
Manual Gas Tight Syringes
Gas tight syringes for manual injections on GC instruments; includes fixed-needle, removable-needle formats in various sizes, needle gauges, needle point styles, and terminations; includes zero dead-volume and headspace syringes.
- (18)
- (15)
- (35)
- (7)
- (96)
- (29)
- (1)
- (66)
- (7)
- (1)
- (2)
- (9)
- (1)
- (1)
- (2)
- (26)
- (1)
- (2)
- (47)
- (1)
- (11)
- (63)
- (47)
- (24)
- (5)
- (60)
- (7)
- (50)
- (4)
- (13)
- (11)
- (2)
- (91)
- (10)
- (73)
- (25)
- (12)
- (14)
- (48)
- (10)
- (9)
- (8)
- (10)
- (23)
- (1)
- (1)
- (1)
- (157)
- (11)
- (1)
- (4)
- (5)
- (1)
- (3)
- (107)
- (110)
- (1)
- (57)
- (2)
- (2)
- (16)
- (7)
- (9)
- (49)
- (16)
- (49)
- (61)
- (1)
- (2)
- (1)
- (5)
- (9)
- (255)
- (1)
- (8)
- (1)
- (8)
- (12)
- (327)
- (13)
- (14)
- (6)
- (192)
- (1)
- (2)
- (15)
- (1)
- (1)
- (1)
- (1)
- (4)
- (2)
- (24)
- (4)
- (9)
- (2)
- (12)
- (11)
- (6)
- (2)
- (6)
- (2)
- (28)
- (1)
- (3)
- (17)
- (2)
- (1)
- (1)
- (2)
- (1)
- (8)
- (1)
- (8)
- (5)
Filtered Search Results

Hamilton™ 700 and 1700 Series Gastight™ and Microliter™ Digital Syringes: N Termination
Easily achieves precision up to 0.5% while dispensing volumes from 500μL down to 50nL
Accuracy | ±0.5% |
---|---|
Length (Metric) | 51 mm |
Length (English) | 2 in. |
Quantity | Ea. |
Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
Length (English) Needle | 2 in. |
For Use With (Application) | Analytical instrument calibration (AA/ICP, GC, HPLC) , prepare standards and spike samples, eliminates parallax errors by providing a digital readout on its integrated LCD screen and also used for pipetting and HPLC injections |
Hamilton™ 700 and 1700 Series Gastight™ and Microliter™ Digital Syringes
Easily achieves precision up to 0.5% while dispensing volumes from 500μL down to 50nL
Needle Point Number | 2 |
---|---|
Length (Metric) | 51 mm |
Length (English) | 2 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | Analytical instrument calibration (AA/ICP, GC, HPLC) , prepare standards and spike samples, eliminates parallax errors by providing a digital readout on its integrated LCD screen and also used for pipetting and HPLC injections |
Accuracy | ±0.5% |
Connection Type | Removable |
Max. Temperature (English) | 239°F |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Length (English) Needle | 2 in. |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |
Hamilton™ 700/700 Microliter™: KH Termination
Syringes have a built-in syringe guide, designed to prevent the plunger from bending and pulling out of the syringe
Needle Point Number | 3 |
---|---|
Length (Metric) | 70 mm |
Length (English) | 2.75 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | Designed for liquid sampling to achieve the highest level of accuracy and precision possible, for use with HPLC injection valves and for sample pipetting |
Max. Pressure | 6000 psi |
Product Type | MicroliterGeneral Purpose Syringe |
Connection Type | Knurled Hub |
Max. Temperature (English) | 239°F |
Needle Point Style | Blunt |
Length (English) Needle | 2.75 in. |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |
Hamilton™ 600 Microliter™ Syringes
The 600 series syringes are a half stroke version of the original 700 series syringes. This series of syringes is ideal for dispensing volumes from 0.25 μL up to 5 μL. The 600 series is often used in applications that require one handed operation because of the short stroke length and the reinforced plunger.
Needle Point Number | 3 |
---|---|
Length (Metric) | 51 mm |
Length (English) | 2 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | Designed for applications that require one-handed operation because of the short stroke length and the reinforced plunger |
Max. Pressure | 2000 psi |
Diameter (Metric) Inner Needle | 0.13 mm |
Product Type | Microliter Syringe |
Diameter (Metric) Outer | 6.6 mm |
Connection Type | Removable |
Max. Temperature (English) | 239°F |
Diameter (English) Outer | 0.26 in. |
Needle Point Style | Blunt |
Diameter (Metric) Outer Needle | 0.71 mm |
Length (English) Needle | 2 in. |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |
Needle Gauge | 22s G |
Diameter (English) Outer Needle | 0.028 in. |
Diameter (English) Inner Needle | 0.005 in. |
Hamilton™ Microliter 700 Cemented Autosampler Syringes, Model 75 N
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: N Termination
Syringes have built-in Chaney Adapters
Includes | Built-in chaney adapter, small plunger wires |
---|---|
Needle Point Number | 2 |
Length (Metric) | 51 mm |
Max. Temperature (English) | 122°F |
Length (English) | 2 in. |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Length (English) Needle | 2 in. |
Max. Temperature (Metric) | 50°C |
For Use With (Application) | Designed for liquid sampling to achieve the highest level of accuracy and precision possible, recommended for septum penetration |
Autoclavable | Not Autoclavable |
Min. Temperature (Metric) | 10°C |
Hamilton™ 1000 Series Gastight™ Purge and Trap GC Syringes
Designed for the analysis of drinking water samples according to EPA purge and trap concentration techniques
Includes | Easy-to-use twist valve |
---|---|
Needle Point Number | No Needle Included |
Product Type | Gastight Syringe |
Connection Type | Luer Tip, Removable |
Needle Point Style | Large RN or LT |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip) |
For Use With (Application) | Designed for the analysis of drinking water samples according to EPA purge and trap concentration techniques |
Min. Temperature (Metric) | 10°C |
Hamilton™ 700 Microliter™ Syringes: RN Termination
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
Needle Point Number | 2 |
---|---|
Length (Metric) | 51 mm |
Product Type | Microliter Syringe |
Connection Type | Removable |
Max. Temperature (English) | 239°F |
Length (English) | 2 in. |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Min. Temperature (English) | 50°F |
Material | PTFE (Tip),Stainless Steel (Plunger) |
Length (English) Needle | 2 in. |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | For dispensing low volumes to achieve the highest level of accuracy and precision possible |
Restek™ Presents SGE Gas-Tight Syringes Fitted with Removable Needle Valve
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Ideal for sample storage and transportation.
Includes | Shut-off valves |
---|---|
Diameter (Metric) Inner Needle | 0.34 mm |
Product Type | SGE Gas-Tight Syringe Fitted with Removable Needle Valve |
Connection Type | Removable |
Quantity | Ea. |
Diameter (Metric) Outer Needle | 0.64 mm |
For Use With (Application) | For sample storage and transportation. |
Needle Gauge | 23 G |
Diameter (English) Outer Needle | 0.025 in. |
Diameter (English) Inner Needle | 0.0132 in. |
Restek™ Presents Hamilton Syringes for Waters U6K Valves
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For Waters U6K Valves.
Needle Point Number | 3 |
---|---|
For Use With (Equipment) | Waters U6K Valves |
Product Type | Hamilton Syringes for Waters U6K Valves |
Connection Type | Removable |
Needle Point Style | 3 |
Quantity | Ea. |
Length (English) Needle | 1.97 in. |
Needle Gauge | 25s G |
Restek™ Presents Hamilton Priming Syringe for Waters 6000, 6000A, 501, 510, 590, 610 and 610E HP
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For Waters 6000, 6000A, 501, 510, 590, 610, and 610E HPLC Pumps.
Restek™ Presents Hamilton PTFE Fluorocarbon Resin-Tip, Gas-Tight Syringes: Needle: LTN
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Suitable for gases or liquids.
Needle Point Number | 2 |
---|---|
Diameter (Metric) Inner Needle | 0.41 mm |
Product Type | Hamilton PTFE Tip, Gas-Tight Syringes |
Needle Point Style | 2 |
Quantity | Ea. |
Diameter (Metric) Outer Needle | 0.72 mm |
Material | PTFE (Tip) |
Length (English) Needle | 2 in. |
For Use With (Application) | Suitable for gases or liquids for maximum inertness |
Needle Gauge | 22 G |
Diameter (English) Outer Needle | 0.028 in. |
Diameter (English) Inner Needle | 0.0162 in. |
Restek™ Hamilton™ Micro-Volume Positive Displacement Syringe, 2.0μL
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Use these syringes for accurate, high precision injections. Restek™ Hamilton™ Micro-Volume Positive Displacement Syringes are designed to contain the sample in the needle with full plunger displacement, ensuring no dead volume.